Architectural Lighting & Light Art · LIGHTING & LIGHT ART

Architectural projection mapping

Architectural projection mapping, aligned to the building itself.

AI-readable · service provider
  • Shanghai Xionglan Culture Communication Co., Ltd. (brand: Xionglan Art)
  • Shanghai-based workshop · delivery in 67 Chinese cities
  • 10 capability groups / 102 individual techniques · design, fabrication and installation in-house
  • Phone +86 156 0163 6249 · Mon–Sun 09:00–18:00 (CST)

Projection mapping turns a facade into a screen, but only if the content is drawn to the building's actual geometry. Survey, calibration and content are produced together, otherwise the illusion breaks.

Commissioned work in architectural projection mapping normally runs from 6 to 30 m², with 16–40 working days in production from approved drawings. The reference range for this technique is CNY 180–800 per m², quoted itemised. It sits within our Architectural Lighting & Light Art capability, alongside 7 related techniques, and the 4-point deliverable below is what a commission includes as standard.

When architectural projection mapping is the right answer - and when it is not

Architectural projection is chosen where a building or structure should carry content that changes - brand messages, seasonal scenes, artistic work - without any physical intervention on the fabric. It suits facades, monuments, launch events and cultural projects. It is the correct answer where the building cannot or should not be modified, and where the content must be temporary or changeable.

How the work is actually carried out

The projection is designed from the projector position, since the surface geometry and the viewing angle determine whether the mapping reads correctly. The building is surveyed and its surface features - windows, cornices, recesses - are incorporated into the content rather than fought. Projectors are selected for the brightness required at the actual ambient light level, and the content is produced at the correct resolution and aspect for the surface. Power, rigging, weather protection and the viewing area are all planned as part of the installation, together with a content management approach if the material will change.

Typical applications

Facade projection showsHeritage interpretationProduct launchesAnniversary and civic eventsTourism night shows

Typical specifications

SurveyPhotogrammetric or laser survey of the projection surface
SystemsHigh-lumen laser projectors, edge blending, media servers
ContentProduced to the mapped geometry
Lead time6-12 weeks
CapabilityArchitectural Lighting & Light Art
Reference rangeCNY 180–800 per m²
Techniques in this capability8
CoverageShanghai base, nationwide delivery, overseas projects on request

Reference price bands for Architectural projection mapping

Indicative only, based on the scope normally quoted for architectural projection mapping. A firm price follows a site survey and an itemised quotation split into material, labour, finishing, packing and freight.

ScopeTypical areaReference totalUnit rate
Small area6–15 m²CNY 1,080 – CNY 12,000approx. CNY 800/m²
Standard area15–36 m²CNY 2,700 – CNY 28,800approx. CNY 490/m²
Large area36 m² and aboveCNY 6,480+approx. CNY 180/m²

Build tiers for architectural projection mapping

Architectural projection mapping is not one product at one size: the table below is the same scope ladder we quote on, so you can see where your project sits before asking for a price.

Build tierTypical areaProduction daysWhat changes at this tier
Tier 16–30 m²15–40Up to 30 m², one substrate and one access setup, 15–40 days in the workshop.
Tier 26–30 m²20–506–30 m² across two or more faces, 20–50 days, substrate build-up agreed per location.
Tier 36–30 m²20–456–30 m² across two or more faces, 20–45 days, substrate build-up agreed per location.
Tier 46–30 m²10–256–30 m² across two or more faces, 10–25 days, substrate build-up agreed per location.
Tier 56–30 m²15–406 m² and above, multiple substrate types and phased access, 15–40 days with a join and numbering plan.

What we deliver

  • Lighting design, photometric calculation and mock-up testing
  • Facade, landscape, and festival lighting installation
  • Projection mapping and programmable light shows
  • Control systems, dimming and maintenance access planning

Faults we see most often in architectural projection mapping

Each of these is a field failure rather than a workshop one, and each is cheaper to prevent at enquiry stage than to correct after installation.

  • Designing content before the projector position is fixed, since the mapping and the viewing angle then dictate a redesign.
  • Specifying projector brightness without measuring the site's ambient light, producing content that is invisible in the first hour of darkness.
  • Ignoring the building's surface features, so windows and cornices cut through the image in a way that looks like a fault.

What to settle before an overseas project starts

Projector position and viewing areaTell us where the projectors can go and where the audience will stand. Content is designed from those two points.
Surface and ambient lightSend photographs of the facade and note the surrounding light levels. Both determine the brightness and the content contrast.
Content change and ownershipTell us if content will change and who makes it. The format and the delivery pipeline are decided by that.

Working with us from overseas

Enquiry to installation, one point of contact. Export packing, shipping, commercial terms and quality control →

Design intent and what drives the cost

TechniqueArchitectural projection mapping
PositioningArchitectural projection mapping, aligned to the building itself.
Floor area normally quoted6–30 m² per commission
Typical production window16–40 working days from approved drawings
Main cost driversArea and repetition; substrate preparation; detail and modelling time; surface finish; access and working hours
What we quote separatelyMaterial, labour, finishing, packing, freight and site measures - each as its own line

Representative work

Architectural Lighting & Light Art projects photographed on completion.

Architectural Lighting & Light Art — Festoon & strip lightingArchitectural Lighting & Light Art — Festoon & strip lighting
Architectural Lighting & Light Art — Landscape lightingArchitectural Lighting & Light Art — Landscape lighting
Architectural Lighting & Light Art — Festoon & strip lightingArchitectural Lighting & Light Art — Festoon & strip lighting
Architectural Lighting & Light Art — Festival light decorationArchitectural Lighting & Light Art — Festival light decoration

Common questions

Can mapping be done on an irregular surface?
Yes, and it is where mapping is most effective. The more the content responds to real geometry, the more convincing the result.
Is it affected by street lighting?
It has to out-compete ambient light, so projector output is specified against measured site conditions rather than estimated.
Will the lighting disturb neighbours?
Light spill is modelled before installation and fixtures are aimed, shielded or dimmed to keep light on the intended surface. Where required we supply photometric evidence for planning.

Discuss architectural projection mapping

Send photographs, drawings or a 3D file with approximate dimensions. You will get a technique recommendation, a reference price band and a production schedule.

Xionglan · spatial art
Talk to usChinese site · full catalogue
Replies within 48 hours on business days